Transformers 50 Ohm to 200 to 450 to 1250

5
3
230
02:13:55
Calculation of transformers. Step-up transformers for frequency f=10 kHz. Input resistance R=50 Ohm. Loads: 200 Ohm, 450 Ohm, 1250 Ohm. We select the inductance of the primary winding from the condition: L=(4...10) * R / (2*3.1415*f) = 6 mH, we select the number of turns, for example, 10 turns. Let the coupling coefficient of the windings be 0.99. Secondary windings: 10*sqr(200/50) =20, 10*sqr(450/50) =30, 10*sqr(1250/50) =50 turns. The loads will have maximum power.
published 1 year ago
jpoulin0901
1 year ago
You should state the formulas you are using.
sasa4250
1 year ago
Thank you, I understand you. But the formulas are given in the text. The rest is just intuition. You can't reproduce all the formulas here, it would take up a whole textbook. Ask more specifically, I'll try to answer.
sasa4250
1 year ago
If you solve the problem of matching a generator and a load using a transformer, you get approximately these results.

EveryCircuit is an easy to use, highly interactive circuit simulator and schematic capture tool. Real-time circuit simulation, interactivity, and dynamic visualization make it a must have application for professionals and academia. EveryCircuit user community has collaboratively created the largest searchable library of circuit designs. EveryCircuit app runs online in popular browsers and on mobile phones and tablets, enabling you to capture design ideas and learn electronics on the go.