Alternator with Hybrid/Transistor Regulator.
3 Coils are connected in a Star Connection, where 2 Phases are connected in Series and the other one is Parallel, resulting in a strengthened Alternator Voltage in opposition to the Phases in a Triangle Circuit, where the Current is higher. 6 Diodes are used to rectify the AC Voltage. 3 additional Diodes for Voltage Regulator. Green LED as Exciter Coil, which gets power when the Voltage produced is lower than 14,4V. Red LED lights up when the Voltage produced is more than 14,4V resulting same Potential on the both sides of Exciter Coil. Lower Transistor turns on when the Alternator Voltage exceeds 14,4V and turns off the other Transistor on the top resulting the Voltage blockade to the Exciter Coil, as a result Magnetfield will decrease and also the amount of Voltage produced, well considering its the real Coil exciter that influences the 3 Coils on the top.
3 Ständerwicklungen sind in Stern Mustern geschaltet. Hier erfolgt eine Addition der zwei Phasenspannungen, da sie in Reihe geschaltet sind. Es kommt zu einer Verstärkung der Generatorspannung gegenüber der Phasenspannung. 6 Leistungsdioden sind um Wechselspannung gleichzurichten eingebaut. Zusätzlich 3 Erregerdioden sind für regelung der Spannung eingebaut. Überschreitet die Generatorspannung den Wert von 14,4 V schaltet untere Transistor die obere Transistor ab, damit wird Spannungversorgung zur Erregerwicklung unterbrochen, welche die Spannungerzeugung unter der Sollwertgrenze begrenzt aber nicht hier in dieser Schaltkreis als es keine einfluss zur Spannung erzeugung hat.
Note: This Circuit is not the final Version.
|