CC method (Linear method) :
1. Multiple : weak 100mΩ shunt voltage (OPAMP x75)
2. Compare : multiplied voltage / potentiometer voltage
3. If (multiplied voltage > potentiometer voltage) off the output mosfet gate
(Output capacitor filtering the high frequency)
Limit current at this circuit : 1 ~ 500mA