Robert_Kidd
5 years ago
A couple of problems here. Two diode drops is about 1.4V and you only have 1V, so increase supply to,say, 10V. Move ground to lower end of capacitor. Finally, to better smooth the rectified signal, increase the capacitor to, say, 10uF.
Robert_Kidd
5 years ago
If you also monitor the ground connection it will stop the oscilloscope auto-ranging.

EveryCircuit is an easy to use, highly interactive circuit simulator and schematic capture tool. Real-time circuit simulation, interactivity, and dynamic visualization make it a must have application for professionals and academia. EveryCircuit user community has collaboratively created the largest searchable library of circuit designs. EveryCircuit app runs online in popular browsers and on mobile phones and tablets, enabling you to capture design ideas and learn electronics on the go.