Simple Regulated Power Supply - help needed

@csmunday
6 years ago
https://everycircuit.com/circuit/5734092453445632
Simple power supply regulated by zener diode intended as a backend to the Riden RD6006. The Riden RD6006 accepts up to 70 volts DC Currently I am struggling with configuring the transformer in the simulation to match the one I am planning to buy. The spec of the transformer I plan to buy is: Rating: 400VA Primary: 2 x 115 volts Secondary: 2 x 24 volts No load voltage: 2 x 25.8 volts Frequency: 50-60hz I plan to connect the primary windings in series and the secondary windings in series. I think i should get a peak voltage (no load) of around (2 * 25.8) * √2 = 72.97 volts. Is this correct? I also think with a 8 ohm resistor I should see 8 Amps flowing at 48 volts. Do I have this correct? How do I configure the transform in EveryCircuit to match the above
Comments