5
0
155
02:20:17
Voltage dividers set the high and low reference. Load is only triggered when the input is IN BETWEEN the high and low window. (input is the DC source with the orange input) Voltage source between the two op amps / comparators is the input. Remove inverter to trigger OUTSIDE of high and low ref. Currently set to trigger between 1/5th and 3/5ths Vcc ( between 1V and 3V ). This is a very useful circuit as it will let you knoe when certain criterias are met from sensor equipment.
published 10 years ago

EveryCircuit is an easy to use, highly interactive circuit simulator and schematic capture tool. Real-time circuit simulation, interactivity, and dynamic visualization make it a must have application for professionals and academia. EveryCircuit user community has collaboratively created the largest searchable library of circuit designs. EveryCircuit app runs online in popular browsers and on mobile phones and tablets, enabling you to capture design ideas and learn electronics on the go.