Transient responses of RLC - 3 different dampening examples

3
5
102
02:06:51
Flip the switch to see 3 different dampening levels. All inductors are 47mH, all caps are 47nF. The RLC resistor values directly affect the dampening of the transient response incurred when 5v is suddenly applied. Under dampening: 400 ohm (blue) Critical dampening: 2 kohm (green) Over dampening: 6 kohm (orange) The ground at the top left is only used to reset the simulation. Make sure sampling speed is 200 micro seconds. http://en.m.wikipedia.org/wiki/RLC_circuit#Transient_response
published 11 years ago
rocketeeter
11 years ago
Make sure sampling speed is 200 micro seconds.
hurz
11 years ago
Good one!
hurz
11 years ago
One thing, I would remove the 2k to ground. So jump up and jump down have the same resistive generator conditions, zero ohm.
rocketeeter
11 years ago
Thanks for the tip! Edited.
darrhunt
10 years ago
another good demonstration. thanks

EveryCircuit is an easy to use, highly interactive circuit simulator and schematic capture tool. Real-time circuit simulation, interactivity, and dynamic visualization make it a must have application for professionals and academia. EveryCircuit user community has collaboratively created the largest searchable library of circuit designs. EveryCircuit app runs online in popular browsers and on mobile phones and tablets, enabling you to capture design ideas and learn electronics on the go.