00:55:05
High precision differential LiPo cell monitor for ADC input on Arduino or any microcontroller ADC input. All resistor pair must be replaced with (10K) 10 turn trim (check second circuit). My online robot experiment : https://www.serveurperso.com/?page=robot
published 9 years ago
sircube
9 years ago
Swap all the op-amps input pins
hurz
9 years ago
Yes, for a real implementation a swap is needed. And why not set all resistors to lets say 10kOhm? This would reduce the complexity and lowers also the current drawn from lipo's. A 1:1 differential amp normal setup. Have fun.
Serveurperso
9 years ago
Yes I know all must be 10k (10k trim pot for precision) but 1k is the default value and faster to setup for the simulation
hurz
9 years ago
10k is not a must. I just saw your values are different to 1k, now i guess you just demonstrated the tolerance, that is fine.
Serveurperso
9 years ago
What is the real world best value for my trims? i have a lot of 25k or 50k trim. i solved the reversed input.
Serveurperso
9 years ago
I make another circuit with trims

EveryCircuit is an easy to use, highly interactive circuit simulator and schematic capture tool. Real-time circuit simulation, interactivity, and dynamic visualization make it a must have application for professionals and academia. EveryCircuit user community has collaboratively created the largest searchable library of circuit designs. EveryCircuit app runs online in popular browsers and on mobile phones and tablets, enabling you to capture design ideas and learn electronics on the go.