Transformer is 500:57 instead of 10:1 to account for the filter stage later. Diode bridge rectifies the full wave. 4-stage π filter with frequency cutoff of 12 Hz and 4.8 kOhm characteristic load impedance (2 Watts @ 12 Volts). Voltage regulating reverse biased zener diode set to 12 Volts.