Rg(Green) and Ro(Orange)
Output (Blue)
C (Red)
Duty Cycle: = Rg + Ro / Rg + 2Ro
Frequency: F = 1.44 / (Rg+2Ro)C
For best results, dont exceed the indicated limits for component values.
Rg > or = 1k
Ro > or = 1k
Rg + Ro < or = 3.3 M